Posted on May 22, 2017 by dean
Q: I’m using hydrogen fluoride used in a manufacturing process to make refrigerants. I know it’s very corrosive and have tried both hastelloy and inconel fasteners, which I thought were super corrosion resistant. What am I doing wrong because the acid is still eating them? Should I try Tantalum? A: … Continue reading →
Posted in Corrosion Resistance, FAQs, Specialty Metal Fasteners | Tagged aeration, Alloy 400, Fluoride layer, Fluoride passive layer, Hastelloy, HF, Hydrofluoric acid, Monel, Monel 400, oxidizing salts, tantalum | Leave a comment